GAS Equipment
Anywhere, anytime
- GAS EQUIPMENTS
-
LPG PRESSURE REGULATOR
- BACK CHECK VALVE(KCV-8L), BACK CHECK VALVE(KCV-8S)
- LPG DISPENSER
- AIR HEATING VAPORIZER FOR LPG
- CAROUSEL FOR LPG FILLING SYSTEM & LPG CYLINDER
- DIGITAL AUTO GAS FILLER
- GAS FILLER & POS SYSTEM
- FILLING HEAD
- GAS COMPRESSOR
- LPG PUMP & LPG FEED PUMP SKID
- OILFREE SCROLL AIR COMPRESSOR
- LPG TANK & TANK LORRY(BULK)
- GLOBE VALVE & CHECK VALVE & STRAINER & ETC
- SAFETY VALVE & EMMERGENCY SHUT OFF VALVE(E.S.V)
- FLANGE END BALL VALVE
- MANUAL VALVES
- STAINLESS STEEL HIGH PRESSURE BALL VALVES
- CRYOGENIC VALVES
- GAS DETECTOR & CONTROLLER
- GAS SHUT OFF DEVICE & WIRE DIAGRAM
- LPG PRESSURE REGULATOR
- CONTROL VALVE & ON-OFF VALVE
- FLOW METER
- LEVEL GAUGE FOR STORAGE TANK
- LEVEL GAUGE FOR LPG TANK LORRY
- PRESSURE & TEMPERATURE INSTRUMENTS
- FUSE COCK, PIGTAIL HOSE & TWIN HOSE
- METAL FLEXIBLE HOSE FOR GAS SYSTEM
- OTHER LPG HOSE
- PIPE FITTING & FLANGE
- EXPLOSION PROOF BOX & ETC
- FIRE-PROTECTION ELECTRIC EQUIPMENT
- PE PIPE & FITTING
- PEN STYLE & PORTABLE GAS LEAK DETECTORS
- SOLENOID VALVE & ETC
- VARIOUS LPG FILLING & USING SYSTEM
- LPG PRESSURE REGULATOR III
LPG
PRESSURE REGULATOR III
LPG
PRESSURE REGULATOR III
HYR 1ST STAGE LOW AND MIDDLE LOW PRESSURE REGULATOR
The compact design of Single stage regulator's makes convenient connection with gas cylinder. The outlet connection can be selected either hose or PT type which enable to connect with hose or pipe. Also the internal relief valve is equipped in low pressure type for the safety
SPECIFICATIONS
Left/Right Scroll
MODEL | CAPACITY (kg/h) |
INLET-PRESSURE (MPa) |
OUTLET SETTING -PRESSURE (P2) |
OUTLET -PRESSURE (MPa) |
INTERNAL RELIEF WORKING PRESSURE (kPa) |
CONNECTION | INTERVAL (mm) |
APPLICATION | |
---|---|---|---|---|---|---|---|---|---|
INLET | OUTLET | ||||||||
HYR-4 | 4 | 0.07-1.56 | 2.8 kPa | 2.8 kPa(P2) ±0.5 | 7.0 ±1.4 | Pol Handle L.H W22.5*14T | Hose end | 167 | Household |
HYR-5 | 5 | 0.07-1.56 | 2.8 kPa | 2.8 kPa(P2) ±0.5 | 7.0 ±1.4 | PT 1/2B | 162.5 | Household & Commercial | |
0.1-1.56 | 6, 10, 15, 20, 25 kPa | (P2) ±Within 20% | No Relief | ||||||
HYR-7 | 7 | 0.07-1.56 | 2.8 kPa | 2.8 kPa(P2) ±0.5 | 7.0 ±1.4 | 170 | |||
0.1-1.56 | 6, 15, 25 kPa | (P2) ±Within 20% | No Relief | ||||||
HYR-12 | 12 | 0.1-1.56 | 2.8 kPa | 2.8 kPa(P2) ±0.5 | 7.0 ±1.4 | PT 1/2B | PT 3/4B | 188 | |
HYR-20 | 20 | PT IB | |||||||
HYR-35 | 35 |
LIQUID CHANGEOVER DEVICE
It is automatically executes changeover function from the service side to reserve side for two separate LPG supply lines which is equipped with vaporizer. Indicator color is marked red(means gas is empty), reserve side gas is inflow and service side gas cylinder is exchanged.
FEATURES
- Compact and light design allows easy installation and can be used low gas consumption place
- Using 3 way valve, no deterioration caused by metal abrasion.
- Service side and reserve side is divided with convert handle.
- It could be adjusted according to below table with changeover pressure setting bolt
SETTING INTERVALL | 21mm | 16mm | 12mm | 7mm |
---|---|---|---|---|
Setting Changeover pressure | 0.05MPa | 0.1MPa | 0.15MPa | 0.2MPa |
- Manual changeover function with manual changeover knob
SPECIFICATIONS
Left/Right Scroll
MODEL | CAPACITY (kg/h) |
INLET-PRESSURE (MPa) |
CHANGEOVER PRESSURE (MPa) | CONNECTION | INTERVAL (mm) |
APPLICATION | |
---|---|---|---|---|---|---|---|
INLET | OUTLET | ||||||
HLX-301A | Max 300 | (Changeover Pressure *∆P) ~1.56 | 0.05 ~ 0.2 | 20A-20K Flange | 315 | Industrial |